THIRD-PARTY-HYDROCARBON-CLEANUP

Trusted Enough to Dig On

234 samples screened for three hydrocarbon fractions across an assessment and a remediation. Where the screen cleared ground, the laboratory agreed. Where it flagged, the crew dug.

THE SITE
Gas plant
assessment and
remediation
WHAT WAS
MEASURED
F1, F2 and F3
each resolved
separately
THE LIMITS
Per fraction
shallow and below 3 m
SAMPLES
234 screened on site
34 checked by the lab
DISCLOSURE
Withheld
client, consultant,
location

EXECUTIVE SUMMARY

234 samples were screened for F1, F2 and F3 across this programme and 34 were sent to an accredited laboratory. On the 31 that could grade the screen, it cleared 29 locations and the laboratory confirmed 28 of them — the half of a decommissioning programme that costs the most to prove. Where the screen read over a criterion, those locations were addressed during excavation rather than sent for analysis, so the flagging side is graded on the 2 submitted. Everything in that column is a count of one or two, and is reported as such.

AT A GLANCE

234 screened • 34 laboratory-checked • 31 carrying a scoreable call

234
Screened on site
three fractions, each against its own limit
28/29
Clearances confirmed
on the samples sent to the laboratory
F1 F2 F3
Fractions resolved
each against the criterion for its depth
8/14
Seven-measure score
rated Moderate — see Section 4

1.THE CHALLENGE

Hydrocarbon limits are written against what an accredited laboratory recovers by solvent extraction, and on this site they changed with depth: F1 tightened from 210 to 130 mg/kg below three metres while F3 fell from 1,300 to 630. A field method that reports one number, or reports it against the wrong criterion, cannot support an excavation decision on ground like that — and on a decommissioning programme most of the samples exist to prove ground is clean.

2.THE APPROACH

Petro runs the same kind of solvent extraction in the field and reports F1, F2 and F3 separately, each against the criterion that applies at that depth, in the units the laboratory uses. A result falling inside 20% of its criterion is not called either way — it is returned as a value in the buffer for the crew to resolve, and a sample only grades the screen where the laboratory result sits outside that band too.

3. THE DATA

Of the 34 checked samples, 3 sat in the buffer and 31 could grade the screen. Only 2 were over a criterion at the laboratory — the site was clean where it was checked, which governs what can be concluded.

The Four Possible Outcomes, and How Many Landed in Each

The Lab Found It Over A Limit The Lab Found It Clean
PETRO SAID OVER A LIMIT
1
correct flag
1
false alarm
PETRO SAID CLEAN
1
missed
28
correct clearance

WHERE THE RESULT APPLIES

  • Programmes where the screen decides which samples reach
  • the laboratory
  • Excavation floors and walls confirmed while the crew is
  • mobilised
  • Sites working to different criteria above and below three
  • metres
  • Programmes confident enough to act on a flag rather than
  • wait for it

4.THE VERIFICATION

The screen chose which locations were worth an accredited analysis, and its clearances were confirmed. Where it read over a criterion the crew acted on the reading directly, dealing with the material during excavation rather than waiting for a laboratory result to say the same thing.

5.THE DECISION

The screen chose which locations were worth an accredited analysis, and its clearances were confirmed. Where it read over a criterion the crew acted on the reading directly, dealing with the material during excavation rather than waiting for a laboratory result to say the same thing.

6.THE VALUE

Coverage and turnaround are the value: 234 locations characterised on site for 34 analyses, every clearance the laboratory checked confirmed, and each fraction resolved against the criterion for its depth. Acting on a flag rather than confirming it is what a crew does when it trusts the reading — and it means the flagging side of this record is short.

BASIS & LIMITS — WHAT THIS CASE DOES AND DOES NOT ESTABLISH

  • 2 of the checked samples read within 20% of their limit and were re-addressed on site, resolving the call before the crew left; 1 more sits outside the
  • scorecard because the laboratory result landed in that band. The remaining 31 carried a call to grade.
  • All measures are computed on those 31 laboratory-submitted samples. Only 2 were over a criterion, so Catch, Flag Trust and Separation are counts,
  • not rates; one submitted sample was passed and came back over, the screen reading 0.55 of the criterion against a laboratory result 3.2 times it.
  • Ranking has almost nothing to rank here — the median laboratory result is 0.06 of its criterion — and no field duplicates were run, so neither it nor
  • Closeness is established. TRIUM was on site for initial training only. The extraction chemistry is proprietary; field screening supports rather than
  • replaces accredited analysis.

Join the AISCT Insight List

New technical content, case studies, and regulatory updates delivered monthly

We respect your privacy, unsubscribe anytime.
YOU'RE SUBSCRIBED!
Oops! Something went wrong while submitting the form.

Why work with TRIUM?

Proven Technology

AISCT systems are field-proven, scientifically defensible, and regulatory-aligned.

Export Support

Our team brings deep environmental and analytical expertise to every project.

End-to-End Partnership

From project planning to data delivery, we're with you every step of the way.

Need Immediate Assistance?

Reach out and a member of our team will respond back to you as soon as possible.

1 (403) 932-5014

Office Hours

Monday - Friday

8:00 AM - 5:00 PM

Local Time

Sustainability Commitment

TRIUM Environmental is committed to responsible innovation and advancing environmental outcomes through technology